Thermo King Alarm Codes Fix
Thermo Assistance is a multi-lingual communication tool designed to put you in direct contact with an authorized Thermo King dealer. Thermo Assistance should only be contacted for breakdown and repair assistance. To use this system, you need the following information before you call: (phone charges will apply). Contact Phone Number.
- Manuals and User Guides for Thermo King TriPac EVOLUTION. We have 1 Thermo King TriPac EVOLUTION manual available for free PDF download: Operator's Manual Thermo King TriPac EVOLUTION Operator's Manual (50 pages).
- Thermo King Straight Truck Units – Most Popular # 1 MD 200 # 2 TS 300 # 3 TS 500 # 4 RD II- SR. Thermo King Trailer Units – Most Popular # 1 SB-III SR # 2 SB- 210/210+ # 3 SB-310/310+ #4 SB 400 # 5 Spectrum. Thermo King Alarm Codes Defined: 00 NO ALARMS EXIST; 01 MICROPROCESSOR POWER UP RESET.
- Close Filter Dealer Service Selection. Truck & Trailer Sales & Service; Truck & Trailer Service Only; Truck & Trailer Service Affiliate; Truck & Trailer Mobile Service.
- Details
- Category: Thermoking Tamir ve Bakım
- Published on 11 February 2012
- Written by Super User
- Hits: 16942
For the following units;
SB-III 30 SR+,SB-III 30 SR TCI-2, Super II 30 SR+Thermoguard µP IV, Super II SR TCI-2 Thermoguard
µPIV, SB-190, SB-200, SB-300, SB-400, Super II 190 ThermoguardµP VI Controller and SB-210, SB-310,SB-410 with SR-2Controller.
Thermoking Alarm Codes List
0. | No Alarms Exist |
2. | Evaporator Coil Sensor |
3. | Control Return Air Sensor |
4. | Control Discharge Air Sensor |
5. | Ambient Air Sensor |
6. | Coolant Temperature Sensor |
7. | Engine RPM Sensor |
9. | High Evaporator Temperature |
10. | High Discharge Pressure |
11. | Unit Controlling on Alternate Sensor |
12. | Sensor Shutdown |
13. | Sensor Check |
15. | Glow Plug Check/Intake Air Heater |
17. | Engine Failed to Crank |
18. | High Engine Coolant Temperature |
19. | Low Engine Oil Pressure |
20. | Engine Failed to Start |
21. | Cooling Cycle Check |
22. | Heating Cycle Check |
23. | Cooling Cycle Fault |
24. | Heating Cycle Fault |
25. | Alternator Check |
26. | Refrigeration Capacity Check |
27. | Motor RPM High |
28. | Pre-Trip Abort |
29. | Defrost Damper Circuit |
30. | Defrost Damper Stuck Closed |
31. | Oil Pressure Switch |
32. | Refrigeration Capacity Low |
33. | Check Engine RPM |
35. | Run Relay Circuit |
36. | Electric Motor Failed to Run |
37. | Engine Coolant Level |
38. | Electric Phase Reversed |
39. | Water Valve Circuit |
40. | High Speed Circuit |
41. | Check Engine Coolant Temperature |
42. | Unit Forced to Low Speed |
43. | Unit Forced to Low Speed Modulation |
44. | Check Fuel System |
45. | Hot Gas Bypass or Hot Gas Bypass Circuit |
46. | Check Air Flow |
48. | Check Belts or Clutch |
50. | Reset Clock |
53. | Economizer Valve Circuit |
54. | Test Mode Time-Out |
55. | Check Engine Speeds |
61. | Low Battery Voltage Check |
62. | Ammeter Out of Calibration Range |
63. | Engine Stopped – Reason Unknown |
64. | Pretrip Reminder |
66. | Low Engine Oil Level |
67. | Liquid Line Solenoid |
70. | Hourmeters Failure |
71. | Maintenance Hourmeter 4 Exceeds Set Time Limit |
72. | Maintenance Hourmeter 5 Exceeds Set Time Limit |
73. | Maintenance Hourmeter 6 Exceeds Set Time Limit |
74. | Controller Reset to Defaults |
75. | Internal Fault Codes |
76. | Internal Fault Codes |
77. | Internal Fault Codes |
78. | Internal Fault Codes |
79. | Data Log Overflow |
80. | Compressor Temperature Sensor |
81. | High Compressor Temperature |
82. | High Compressor Temperature Shutdown |
83. | Low Coolant Temperature |
84. | Restart Null |
85. | Forced Unit Operation |
86. | Discharge Pressure Sensor |
87. | Suction Pressure Transducer |
89. | Electronic Throttling Valve Circuit |
90. | Electric Overload |
91. | Electric Ready Input |
92. | Sensor Grades Not Set |
93. | Low Compressor Suction |
94. | Loader #1 |
95. | Loader #2 |
96. | Low Fuel Level |
98. | Fuel Level Sensor |
99. | High Compressor Pressure Ratio |
108. | Door Open Time-Out |
109. | High Discharge Pressure |
111. Unit Configuration | |
117. Auto Switch to Electric | |
118. Auto Switch to Diesel | |
121. Liquid Injection Circuit | |
122. Diesel/Electric Relay Circuit | |
127. Setpoint Not Entered | |
128. Engine Run Time Maintenance Reminder #1 | |
129. Engine Run Time Maintenance Reminder #2 | |
130. Electric Run Time Maintenance Reminder #1 | |
131. Electric Run Time Maintenance Reminder #2 | |
132. Total Unit Run Time Maintenance Reminder #1 | |
133. Total Unit Run Time Maintenance Reminder #2 | |
134. Power On Hours | |
135. Spare Digital Inputs | |
136. Spare Digital Outputs | |
203. | Display Return Air Sensor |
204. Display Discharge Air Sensor |
Thermoking Alarm Codes Documents: PDF Download , DOC Download
Thermoking Alarm Codes Fix: PDF Download
Коды ошибок ТЕРМО КИНГ: Download
A guide for troubleshooting alarm codes or fault codes on trailer and truck mounted Thermo King refrigeration units.
This guide lists all the Thermo King alarm codes that could go off on a Thermo King unit. These alarm codes will appear on straight truck refrigeration units and trailer refrigeration units. Just scroll down this page to find out what your alarm code means. If you need help further troubleshooting your Thermo King unit, visit the Mobile Reefer Repair in Sacramento,CA.
Thermo King Alarm Code & Description:
204 issue redundant discharge air sensor
203 issue with redundant return air sensor
137 issue with damper motor heater output
136 issue with spare digital outputs
Thermo King Repair Shops
135 issue with spare digital inputs
134 controller power on hours
133 total unit run time maint reminder # 2
132 total unit run time maint reminder # 1
131 engine run time maint reminder # 2
130 engine run time maint reminder # 1
129 engine run time maint reminder # 2
128 engine run time maint reminder # 1
127 setpoint not entered
126 issue with back pressure regulator
125 issue with tank level sensor
124 issue with evap coil outlet temp sensor
123 issue with evap coil inlet temp sensor
122 issue with diesel/electric circuit
121 issue with pmw liquid injection circuit
120 issue with alternator excite circuit
119 reserved for cr
118 auto switch from electric to diesel
117 auto switch from diesel to electric
116 issue with high pressure cut in switch
115 issue with high pressure cut out switch
114 multiple alarms- can not run
113 issue with elerctric heat circuit
112 issue with remote fans
111 unit not configured correctly
110 issue with suction line sol circuit
109 issue with high discharge pressure sensor
108 door open timeout
107 issue with condeensor inlet sol circuit
106 issue with purge valve circuit
105 issue with receiver tank press sol circuit
104 issue with remote fan speed
103 low heater fuel level
102 low evaporator coil temperature
101 controlling on evap coil outlet temp
100 heater fan failure
99 high compressor pressure ratio
98 issue with fuel level sensor
97 failed remote return air sensor
96 low fuel level
95 issue with loader # 2 circuit
94 issue with loader # 1 circuit
93 low compressor suction pressure
92 sensor grades not set
91 issue with electric ready input
90 electric overload
89 issue with electronic throttling valve circuit
88 reserved for cr
87 issue with suction pressure sensor
86 issue with discharge pressure sensor
85 forced unit operation
84 restart null
83 low engine coolant temp
82 high compressor temp shutdown
81 high compressor temp
80 issue with compressor temp sensor
79 internal data logger overflow
78 data log eprom failure
77 controller eprom check sum faliure
76 controller eprom failure
75 controller ram failure
74 controlleer reset to defaults
73 hourmeter 6 exceeds set time limit
72 hourmeter exceeeds set time limit
71 hourmeter 4 exceeds set time limit
70 hourmeter failure
69 issue with remagnetization circuit
68 internal controller fault code
67 issue with liquid line solenoid circuit
66 low engine oil level
65 abnormol temperature differential
64 pretrip reminder
63 engine or vapor motor stopped
62 ammeter out calibration
61 low battery voltage
Thermo King Code 20 Repair
60 issue with boost circuit
59 issue with condenser fan high speed
58 issue with condenser fan low speed
57 issue with evaportor fan high speed
56 issue with evaportor fan low speed
55 issue with engine speeds
54 test mode timeout
53 issue with economizer valve circuit
52 issue with heat circuit
51 issue with shutdown circuit
50 reset clock
49 reserved for cr
48 issue with belts or clutch
47 remote sensor shutdown
46 issue with air flow
45 issue with hot gas or hot gas bypass circuit
44 issue with fuel syatem
43 unit forced to low speed modulation
42 unit forced to low speed
41 issue with engine coolant temp
40 issue with high speed circuit
39 issue with water valve circuit
38 electric phase reversed
37 issue with engine coolant level
36 electric motor failed to run
35 issue with run relay circuit
34 issue with modulation circuit
33 issue with engine rpm
32 refrigeration capacity low
31 issue with oil pressure switch
29 defrost damper circuit issue with
28 pretip or self check abort
27 vapor motor rpm high (cr)
26 issue with refrigeration capacity
25 alternator check
24 heating cycle fault
23 cooling cycle fault
22 heating cycle fault
21 cooling cycle check
20 engine ( vapor motor cr) failed to start
19 low engine oil pressure
Thermo King Alarm Codes & Fault Codes For Refrigeration Repair
18 high engine coolant temperature
17 engine failed to crank
16 manual start not completed
15 issue with glow plugs or intake air heater
14 defrosat terminate by time
13 sensor check
12 sensor or digtal input shutdown
11 unit controlling on alternate sensor
10 high discharge pressure (or temp)
09 high evaporator temperature
08 unit running in coil sensor
07 issue with engine rpm sensor
06 issue with coolant temp sensor
05 issue with amibent temp sensor
04 issue with discharge air sensor
03 issue with return air sensor
Thermo King Code 17
02 issue with evaporator coil sensor
See Full List On Ctk-parts.eu
01 microprocessor power up reset
00 no alarms exist